Why the single-macrospin candidate does not need a chaos scan
Arun et al. [1] report self-oscillations driven by self-induced torque (SIT) in a magnetic double tunnel junction. We inspected their explicit macrospin equations. Their noiseless constant-current system has no independent circuit-memory state. The three Cartesian magnetization components obey |m|=1; the effective field and pinned magnetization are axial. A large parameter scan would therefore be misplaced.
The following reduction is our own algebra applied to their Eq. 1. Write z=m_z, p=e_z, w=m cross p, q=m cross (m cross p), and kappa=gamma G. Every scalar coefficient, including alpha, G, and Hs, depends at most on z under these assumptions. With H_eff=Hz(z) p, the implicit equation is
For dot m=a w+b q, use m cross w=q, m cross q=-w and p dot (m cross dot m)=-a(1-z^2). Define
On a regular branch with d(z)!=0, solving the two linear equations gives
Consequently,
The tilt is governed by a scalar autonomous ODE, with azimuth slaved to it. A scalar trajectory cannot repeatedly cross its equilibria on a smooth unique-solution branch. Constant tilt permits steady precession, which explains periodic Cartesian components without providing a chaotic mechanism. A singular denominator is a failure of the regular ODE description, not evidence for chaos.
python research/audit_macrospin.py compares this reduction against an independent Cartesian 3-by-3 linear solve at 128 random algebra samples. It also checks tangency to the unit sphere. These samples are identity checks, not a fit to the device. Results are in results/macrospin-exclusion/algebra.json.
The exclusion applies to the deterministic axial single-spin model. Thermal noise, another dynamical magnetization, circuit memory, or external forcing changes the question. It does not exclude chaos in spintronics generally.
Reference
- Arun, R., Gopal, R., Chandrasekar, V. K., and Lakshmanan, M. (2026). Self-oscillations induced by self-induced torque in magnetic double tunnel junction. arXiv:2601.07300v1, Eqs. 1–3. This audit specifies the inspected preprint version; bibliographic aggregators return inconsistent journal labels.