Recovering two Chua state variables from one capacitor voltage
How finely must the first capacitor voltage be sampled to recover the second voltage and the inductor current coordinate ? For the 34 reference cycles, nine equally spaced samples per voltage peak, averaged over a complete period, kept the relative RMS error below 1% for both coordinates at all 16 tested sampling phases. At eight samples per peak, nine families exceeded 1%. These figures assume the correct period and circuit parameters and a noiseless periodic trace. Reference orbits · Per-family errors

From voltage to current
Parlitz and colleagues experimentally drove the subsystem of a Chua receiver with in 1992. Here we use that subsystem to measure how much sampling and calibration accuracy the atlas waveforms require. Parlitz et al., experimental receiver
The equations are and . For a Fourier component with , the periodic response is
For and both roots of have negative real part, so the periodic response is unique. The formula includes the DC component. On the classical slice , the mean of vanishes and the mean of equals minus the mean of . No diode slopes enter the reconstruction. The complementary diode-crossing calculation obtains the input spectrum directly from the periodic orbit’s crossing times and velocities.
Sampling and calibration
For a cycle with local maxima in per period, a sampling rate of nine means observations in one period. The test supplies only those values to the filter and compares reconstructed against the archived orbit on a denser time grid, including between sample times. Error is RMS divided by the standard deviation of the corresponding reference coordinate.
| Samples per peak | Families below 1% on both coordinates | Largest error |
|---|---|---|
| 6 | 0 / 34 | 3.98% |
| 8 | 25 / 34 | 1.35% |
| 9 | 34 / 34 | 0.785% |
| 12 | 34 / 34 | 0.326% |
| 32 | 34 / 34 | 0.0165% |
Raising the assumed by 1% at 32 samples per peak increased the larger coordinate error to 1.98–2.24% across the families. Repeating the sampling study with the coarser archived orbit reconstructions changed the reported errors by at most 0.0035 percentage point. An independent time-domain calculation on a known periodic drive agreed with the filter within in model units at zero and positive loss. Numerical controls
Try it on one period
This example starts with 45 samples of the five-peak S11 voltage. The input is one dimensionless column, with no header or repeated endpoint. The output contains at the same sample times. Use the full period in dimensionless model time.
python research/chua_voltage_reconstruction.py trace results/chua-voltage-reconstruction/S11-x.csv outputs/S11-states.csv --period 14.495247978979704 --beta 14.359245458104963
python research/chua_voltage_reconstruction.py atlas
The second command replays the benchmark from both archived orbit resolutions and writes to outputs/chua-voltage-reconstruction/. The script uses NumPy, SciPy and Matplotlib. Source