Research notes

Recovering two Chua state variables from one capacitor voltage

How finely must the first capacitor voltage xx be sampled to recover the second voltage yy and the inductor current coordinate zz? For the 34 reference cycles, nine equally spaced samples per voltage peak, averaged over a complete period, kept the relative RMS error below 1% for both coordinates at all 16 tested sampling phases. At eight samples per peak, nine families exceeded 1%. These figures assume the correct period and circuit parameters and a noiseless periodic trace. Reference orbits · Per-family errors

Reconstruction errors for 34 periodic Chua orbits versus voltage samples per peak

From voltage to current

Parlitz and colleagues experimentally drove the (y,z)(y,z) subsystem of a Chua receiver with xx in 1992. Here we use that subsystem to measure how much sampling and calibration accuracy the atlas waveforms require. Parlitz et al., experimental receiver

The equations are y˙=x−y+z\dot y=x-y+z and z˙=−βy−γz\dot z=-\beta y-\gamma z. For a Fourier component with s=2πik/Ts=2\pi i k/T, the periodic response is

D(s)=(s+1)(s+γ)+β,Yk=s+γD(s)Xk,Zk=−βD(s)Xk.D(s)=(s+1)(s+\gamma)+\beta,\qquad Y_k=\frac{s+\gamma}{D(s)}X_k,\qquad Z_k=-\frac{\beta}{D(s)}X_k .

For β>0\beta>0 and γ≥0\gamma\ge0 both roots of DD have negative real part, so the periodic response is unique. The formula includes the DC component. On the classical slice γ=0\gamma=0, the mean of yy vanishes and the mean of zz equals minus the mean of xx. No diode slopes enter the reconstruction. The complementary diode-crossing calculation obtains the input spectrum XkX_k directly from the periodic orbit’s crossing times and velocities.

Sampling and calibration

For a cycle with pp local maxima in xx per period, a sampling rate of nine means 9p9p observations in one period. The test supplies only those xx values to the filter and compares reconstructed y,zy,z against the archived orbit on a denser time grid, including between sample times. Error is RMS divided by the standard deviation of the corresponding reference coordinate.

Samples per peak Families below 1% on both coordinates Largest error
6 0 / 34 3.98%
8 25 / 34 1.35%
9 34 / 34 0.785%
12 34 / 34 0.326%
32 34 / 34 0.0165%

Raising the assumed β\beta by 1% at 32 samples per peak increased the larger coordinate error to 1.98–2.24% across the families. Repeating the sampling study with the coarser archived orbit reconstructions changed the reported errors by at most 0.0035 percentage point. An independent time-domain calculation on a known periodic drive agreed with the filter within 2.2×10−122.2\times10^{-12} in model units at zero and positive loss. Numerical controls

Try it on one period

This example starts with 45 samples of the five-peak S11 voltage. The input is one dimensionless xx column, with no header or repeated endpoint. The output contains t,x,y,zt,x,y,z at the same sample times. Use the full period in dimensionless model time.

python research/chua_voltage_reconstruction.py trace results/chua-voltage-reconstruction/S11-x.csv outputs/S11-states.csv --period 14.495247978979704 --beta 14.359245458104963
python research/chua_voltage_reconstruction.py atlas

The second command replays the benchmark from both archived orbit resolutions and writes to outputs/chua-voltage-reconstruction/. The script uses NumPy, SciPy and Matplotlib. Source